Dryer Vent Safety

7 Facts About Dryer Vent Safety, view some different ways that you can prevent your dryer becoming a hazard in your house.

  1. According to manufacturer’s specifications and local codes, dryer ducts must be a minimum 4” in diameter and at least as large as the dryer outlet.
  2. Unless otherwise specified by your dryer’s manufacturer or local code, the developed length of your dryer’s exhaust duct should not exceed 25 feet. (When determining developed length, each 90º turn adds 5 feet to the actual length.)
  3. Dryer vents shall be independent of all other systems and terminate outdoors, not into a chimney, crawl space or attic.
  4. Your outside dryer exhaust vent’s termination hood should be equipped with a back draft damper to ensure that the exhaust doesn’t come back in your home.
  5. Metal transition ducts should be used between the dryer and the exhaust duct.
  6. Flexible transition ducts should never be used in an attic, a crawl space, or inside a wall.
  7. The CSIA Certified Dryer Exhaust Technician credential is the only nationally-recognized credential of its kind.